1、北京市地方标准DB编 号:DB11/T463 -2012备案号:J12270 - 2013胶粉聚苯颗粒复合型外墙外保温工程技术规程Technical specification for external thermalinsulatioii on outer walls with compositedsystems based on mineral binder andexpanded polystyrene granule plaster2012-12-12发布20130401实施北京市住房和城乡建设委员会眸厶岩出 北京市质量技术监督局 口北 京市地方标准胶粉聚苯颗粒复合型外墙外保温工程技术
2、规程Technical specification for external thermalinsulation on outer - walls with compositedsystems based on mineral binder andexpanded polystyrene granule plaster编号:DB11/T463 -2012备案号:J12270 - 2013主编单位:北京振利节能环保科技股份有限公司 批准部门:北京市质量技术监督局实施日期:2013年04月01日2013北京关于发布北京市地方标准胶粉聚苯颗粒复合型外墙外保温工程技术规程的通知京建发2013 32号各
3、区、县住房城乡建设委,各集团、总公司,各有关单位:根据北京市质量技术监督局关于印发2009年北京市地方标 准制修订项目计划的通知(京质监标发2009176号)的要求, 由北京振利节能环保科技股份有限公司主编的胶粉聚苯颗粒复 合型外墙外保温工程技术规程已经北京市质量技术监督局批 准,北京市质量技术监督局、北京市住房和城乡建设委员会共同 发布,编号为 DB11/T463 -2012,代替 DB11/T463 -2007外 墙外保温施工技术规程(胶粉聚苯颗粒复合型外墙外保温系统) 和DBJ/TO1 - 102 - 2005外墙外保温施工技术规程(喷涂硬泡聚 氨酯外墙外保温系统),自2013年4月1日
4、起实施。该规程由北京市住房和城乡建设委员会、北京市质量技术监 督局共同负责管理,由北京振利节能环保科技股份有限公司负责 解释工作。特此通知。北京市住房和城乡建设委员会二。一三年一月十四日关于同意北京市防滑地面工程施工及验收规程等六项地方标准备案的函建标标备2013 28号北京市住房和城乡建设委员会:你委关于六项北京市工程建设地方标准胶粉聚苯颗粒复 合型外墙外保温工程技术规程 、 温拌沥青路面施工及验收规 范 、 无机纤维喷涂工程技术规程 、 居住建筑供热计量施工 质量验收规程 、 外墙外保温施工技术规程(复合酚醛保温板 聚合物水泥砂浆做法)、 防滑地面工程施工及验收规程 申 请备案的函(京建科
5、标备便201301号)收悉。经研究,同意 该六项标准作为“中华人民共和国工程建设地方标准”备案, 其备案号:胶粉聚苯颗粒复合型外墙外保温工程技术规程J12270 - 2013 温拌沥青路面施工及验收规范H2269 - 2013无机纤维喷涂工程技术规程J12268 - 2013居住建筑供热计量施工质量验收规程J12267 -2013外墙夕嵌温施工技术规程(复合酚醛保温板聚合物水泥砂浆做法)J12266 - 2013 防滑地面工程施工及验收规程J12265 -2013该六项标准的备案公告,将刊登在近期出版的工程建设标 准化刊物上。住房和城乡建设部标准定额司 二O一三年二月二十一日前 言本规程为推荐
6、性标准。为实现北京市建筑节能目标,确保外墙外保温工程的施工质 量,根据北京市质量技术监督局关于印发2009年北京市地方标 准制修订项目计划的通知(京质监发200976号),按照北京 市住房和城乡建设委员会的要求,对DB11/T463 - 2007外墙外 保温施工技术规程(胶粉聚苯颗粒复合型外墙外保温系统)和 DBJ/TO1 - 102 -2005外墙外保温施工技术规程(喷涂硬泡聚氨 酯外墙外保温系统)标准进行修订,合编为胶粉聚苯颗粒复 合型外墙外保温工程技术规程。在编制过程中,编制组进行广泛的调査研究,开展专题讨论 和试验,以多种方式征求了国内外有关科研、设计、施工、质 检、监理、墙改等单位的
7、意见,参考了国内外相关标准。本规程修订时总结了近年来我国建筑外墙外保温的设计、施 工、验收和运行管理方面的实践经验和研究成果,适用于居住建 筑、非幕墙式公共建筑的外墙外保温工程和既有建筑节能改造的 外墙外保温工程,也适用于农村建筑的外墙外保温工程。本规程共分8章和4个附录。主要内容是:L总则;2.术 语;3.基本规定;4.性能要求;5.系统构造;6.设计;7.施 工;8.验收;附录A窗口火试验方法;附录B表面抗拉强度试 验方法;附录C沿岩棉丝方向拉伸粘结强度试验方法;附录D 保温层厚度选用表。附录A、附录B、附录C、附录D均为规范 性附录。本规程由北京市住房和城乡建设委员会和北京市质量技术监
8、督局共同负责管理,北京振利节能环保科技股份有限公司负责具 体技术内容的解释。在执行过程中,请各单位注意总结经验,积1 DB11/T 463 - 2012累资料,随时将有关意见和建议反馈给北京振利节能环保科技股 份有限公司(地址:北京市大兴区长子营工业区;邮政编码 W2615),以供今后修订时参考。本规程主编单位:北京振利节能环保科技股份有限公司本规程参编单位:中国建筑科学研究院北京首建标工程技术开发中心中国建筑设计研究院北京市消防科学研究所北京市住房和城乡建设科技促进中心 北京市建设工程物资协会建筑节能专业委员会北京六建集团有限责任公司中国建筑材料检验认证中心朱青林燕成朱春玲 陶驷骥张树君崔荣
9、华 黄凯任琳王庆生 宋晓辉邹海敏李春雷 高巍付海明胡永腾 金鸿祥田亮涂逢祥 顾泰昌刘晓钟本规程主要起草人员:黄振利 季广其 徐晨辉 陈丹林 李晓亮 本规程主要审查人员:杨西伟 游广才目 次1总则 12术语23基本规定44性能要求54. 1 系统54.2组成材料 65系统构造 186 设计 297 施工327. 1一般规定327.2贴砌聚苯板系统施工要点337.3聚苯板现浇混凝土系统施工要点387.4粘贴聚苯板系统施工要点407.5喷涂聚氨酯系统施工要点427.6锚固岩棉板系统施工要点 447.7贴砌增强竖丝岩棉板系统施工要点477.8保温浆料系统施工要点498验收 528.1一般规定528.2
10、主控项目538.3一般项目 54附录A窗口火试验方法56附录B 表面抗拉强度试验方法 62附录C沿岩棉丝方向拉伸粘结强度试验方法641DB11/T 463 2012附录D保温层厚度选用表67本规程用词说明73引用标准名录74条文说明772DB11/T463 -2012Contents1 General provisions 12 Terminology 23 Basic requirements 44 Performance requirements 54. 1 Systems 54.2 Constouctionalmaterials 65 Systems constitation 186 D
11、esign 297 Construction 327. 1 General requirement * 327. 2 Construction key points of adhibit and build polystyrene board system 337. 3 Construction key points of polystyrene board without steel mesh cast - in - place concrete system 387. 4 Construction key points of adhibit polystyrene board system
12、 407. 5 Construction key points of spray polyurethane system 427. 6 Construction key points of anchor rock wool board system 447. 7 Construction key points of adhibit and build vertical silk rock wool board system *. 477. 8 Construction key points of insulating plaster system - 498 Acceptance 528. 1
13、 General requirement 528. 2 Master items 538. 3 Generic items 54Appendix A Windowfire test method 56Appendix B Test method for surface tensile strength ofinsulating board 62Appendix C Test method for bond strength along silk direction of rock wool 64Appendix D The select table of insulation material
14、thickness 67Explanation of wording in this standard 73List of normative standards 74Clause explanation 772DB11/T463 - 20121总 则1.0.1为贯彻国家建筑节能政策和执行北京市建筑节能设计标 准,规范胶粉聚苯颗粒复合型外墙外保温系统的技术要求、施工 做法、试验方法及验收标准,保证外墙外保温工程质量,做到技 术先进、安全可靠、经济合理,制定本规程。1-0.2本规程适用于以混凝土或砌体为基层墙体,采用胶粉聚 苯颗粒复合型外墙外保温系统的新建、改建、扩建居住建筑和非 幕墙式公共建筑
15、外墙外保温工程的设计、施工和验收。1.0.3胶粉聚苯颗粒复合型外墙外保温工程的构造、设计、施 工和验收除应符合本规程外,尚应符合国家及北京市现行的有关 标准和规定。1DBU/T 463 -20122术 语2.0.1胶粉聚苯颗粒复合型外墙外保温系统composited external thennal insulation systems based on mineral binder and expanded polystyrene granule plaster以胶粉聚苯颗粒浆料为保温层,或作为找平层、粘结层与其 它材料的保温层相复合的多种外墙外保温系统,简称胶粉聚苯颗 粒复合型系统。2.0
16、*2 胶粉聚苯颗粒浆料 mineral binder and expanded polystyrene granule plaster由可再分散胶粉、无机胶凝材料、外加剂等制成的胶粉料与 作为主要骨料的聚苯颗粒复合而成的保温灰浆,包括胶粉聚苯颗 粒保温浆料(简称保温浆料)、胶粉聚苯颗粒贴砌保温浆料(简称 贴砌浆料)。2.0.3 玻纤网无机保温浆料包覆增强竖丝岩棉板 vertical silk rock wool board covered with glass fiber mesh inorganic insulation plaster以多条岩棉条为芯材,由玻纤网无机保温浆料防护层包覆长 度
17、方向四个面固定而成的岩棉丝平行于板体厚度方向的长方体板 状制品,简称增强竖丝岩棉板。2. 0. 4 防潮底漆 moistureproof primer用于封闭基层墙面毛孔及水份、浮灰等物质以提高硬泡聚氨 酯与基层墙面有效粘结的底涂材料。2. 0. 5 柔性止水砂浆 waterproof flexible mortar由水泥、石英砂、弹性颗粒及添加剂配制而成的用于门窗口 等处防水、抗渗、堵漏的干粉砂浆。2. 0. 6 窗口 火试验 window fire test2DB11/T463 - 2012一种模拟房间内发生轰燃后火焰从窗口或洞口溢岀而对外墙 外保温系统进行攻击的大型试验。2.0.7 水平
18、准位线level位于窗口火试验模型燃烧室开口顶部上方5000mm的水平测 温线。2.0. 8 防火分仓 fireproof compartment在保温层中,采用不燃保温材料将可燃保温材料分隔成若干 个相互独立的小面积固定尺寸区域的构造。2.0.9 空腔 cavity保温层与基层墙体之间的空间。53基本规定3.0.1胶粉聚苯颗粒复合型外墙外保温工程应满足下列要求:1能适应基层的正常变形而不产生裂缝或空鼓;2能长期承受自重、风荷载和室外气候的长期反复作用而 不产生有害的变形和破坏;3应与基层墙体有可靠连接,避免在地震时脱落;4应具有防止火焰蔓延的能力;5应具有防水渗透性能。3.0.2胶粉聚苯颗粒
19、复合型外墙外保温工程的保温、隔热性能 应符合国家、行业和本市节能设计标准的规定,其防潮设计应符 合现行国家标准GB 50176(民用建筑热工设计规范规定。3.0.3胶粉聚苯颗粒复合型外墙外保温工程各组成部分应具有 物理-化学稳定性。所有组成材料应彼此相容并应具有防腐性。 在可能受到生物侵害(鼠害、虫害等)时,胶粉聚苯颗粒复合型外 墙外保温工程还应具有防生物侵害性能。3.0.4在正确使用和正常维护的条件下,胶粉聚苯颗粒复合型 外墙外保温工程的使用年限不应少于25年。4性能要求4.1系 统4.1.1胶粉聚苯颗粒复合型系统一般性能应符合表4.1.1的 要求。表4.1.1胶粉聚苯颗粒复合型系统一般性能
20、指标试验项目性能指标试验方法涂料饰面面砖饰面耐候性外观无可滲水裂缝,无粉 化、空鼓、剥落现象JGJ 144系统拉伸粘结强度,MPa部.1一面砖与抗裂层拉 伸粘结强度,MPaNO. 4吸水量(浸水24h), g/m2W500抗冲 击性二层及以上3J级首层WJ级水蒸气透过湿流密度,g/(m2 -h)5*0. 85耐冻融外观无可渗水裂缝,无粉 化、空鼓、剥落现象抗裂层与保温层拉伸粘结强 度,MPamo. 1面砖与抗裂层拉伸粘结强 度,MPa部.4不透水性抗裂层内侧无水渗透热阻符合设计要求GB/T 13475DB11/T 463 - 20124.1.2胶粉聚苯颗粒复合型系统对火反应性能应符合表4. 1